Here you’ll find answers to the most common questions about our dental equipment—everything from autoclave servicing schedules to compressor troubleshooting and HTM 01-05 compliance. We’re constantly expanding this resource, so check back often as we add new questions and expert tips. Can’t find what you’re looking for? Simply drop your question in the form at the end of the page, and we’ll get back to you promptly.

Equipment Maintenance & Service

Autoclaves should be serviced at least once a year by a qualified technician. Regular maintenance ensures that pressure, temperature, and sterilization cycles remain effective. Monthly self-inspections and cleaning are also recommended.
Check for visible leaks in hoses or connections, ensure the air filter is clean, and verify that the pressure switch is set correctly. If these steps don’t resolve the issue, consult a technician to inspect the compressor for internal damage or wear.
Signs include recurring malfunctions, outdated features, or discomfort for patients. If repairs exceed 50% of the cost of a new chair or if it no longer aligns with modern practice standards, it’s time to replace it.
Empty and clean the tank daily, use only manufacturer-approved cleaning solutions, and replace the solution after every use. Regularly check the ultrasonic generator and perform a foil test monthly to ensure consistent cavitation.
Class B autoclaves are more versatile and suitable for small practices as they can sterilize a broader range of loads, including wrapped instruments. Class N autoclaves are less expensive but are limited to unwrapped solid items.
DUWLs are prone to biofilm because of small-diameter tubing and low flow. Best practice: flush lines at start/end of day and between patients, use manufacturer-approved antimicrobial treatments or continuous systems, use distilled/deionized/sterile water where the manufacturer requires it, and perform regular microbial testing. Follow CDC/ADA/FDA guidance for DUWL management and document your routine. If counts are high, remediate per the manufacturer’s protocol or contact a waterline specialist.

Troubleshooting & Error Codes

Check for basic issues such as water level, door seal integrity, and blocked vents. Refer to the error code in the user manual for specific troubleshooting steps. If unresolved, contact a professional technician.
Stains may result from hard water deposits, improper detergent use, or inadequate rinsing. Use demineralized water, ensure the correct detergent dosage, and perform regular descaling of the machine.
Error codes vary by make/model, so always check your manufacturer manual first. However, many units share generic alerts: Low Water / “E1”: indicates the chamber water level is below the minimum. Refill with distilled water and inspect inlet filters. Door Seal / “E2”: the door failed to lock or seal. Examine gaskets for wear or debris and replace annually. Temperature Sensor Fault / “E5”: the thermocouple is out of range. Reboot the unit; if persistent, have the sensor tested or replaced. Pressure Leak: cycle aborts if pressure can’t build. Inspect valves, plumbing joints, and the vacuum pump for leaks. For any unfamiliar code, consult your service manual or technical support—overriding alarms can compromise sterilization safety.
First check basic items: correct water level (distilled), clean/undamaged door gasket, no blocked drains or vents, and correct loading (don’t overload). Look at any error codes and compare with the manufacturer manual. If the unit still fails to reach set temperature, it can be due to scale/mineral buildup, a failing heater or temperature sensor, or a failing vacuum/air-removal system, stop using the unit for critical cycles and call a technician. Keep routine descaling and the manufacturer’s preventive maintenance schedule to reduce recurrence.
Instruments should be dry after a completed cycle. Wet instruments commonly result from an ineffective drying phase, incorrect packaging, overloading, or vent/drain problems. First, ensure you’re using the correct cycle (including a drying phase), don’t overload trays, and use manufacturer-recommended wraps or pouches. If problems persist, check the autoclave’s drying fan and drain lines and have a technician inspect the heating/drying element. Occasionally a different packaging or an extended drying time resolves the problem.
Common causes: blockages (debris, amalgam solids), clogged filters, leaks in tubing/joins, or exhausted trap/waste collectors. Smells often indicate venting issues or trapped organic matter. Basic checks: inspect and clean inline filters and cannisters, check for blockages in traps and suction lines, confirm the vent piping is intact/clear and that exterior vents aren’t blocked, and clear or replace separators/filters as recommended. If problem persists, have your engineer check for leaks or failing vacuum pumps. Regularly scheduled suction maintenance prevents many of these problems.

Buying Guidance

Calculate the air consumption for all chairs and additional equipment, ensuring the compressor can handle peak demand. Opt for an oil-free, dry compressor for dental use, and consider noise levels and space requirements.
Consider image quality, radiation dose, compatibility with practice software, and the type of procedures you perform. Look for units compliant with UK radiation protection standards.

Compliance & Regulations

Practices must comply with HTM 01-05 guidelines, which emphasize regular equipment validation, routine cleaning, and maintaining records of sterilization cycles. Annual servicing by certified professionals is mandatory.
Implement a robust decontamination workflow, validate all sterilization processes, maintain equipment logs, and provide staff training. Periodic audits can help identify areas for improvement.
Follow your autoclave manufacturer’s instructions and applicable guidance. General best practice: daily routine physical checks and daily or weekly chemical indicator tests (depending on the indicator type), and weekly biological indicator (spore) testing for most sterilizers (some guidance differs by device and risk) — document all monitoring. Keep records of cycle parameters and remediation steps. For UK practices, align with HTM 01-05 and national standards. If in doubt, follow your device manual and local regulatory guidance.

Practice Efficiency & Sustainability

Consider autoclaves with energy-saving cycles and use biodegradable or reusable sterilization wraps. Switching to distilled water systems instead of single-use bottles also reduces waste.
Use sound-dampening enclosures for compressors, select equipment with low-noise ratings, and place noisy equipment in separate rooms or soundproofed cabinets.

Future Trends & Advancements

Emerging trends include AI-integrated diagnostic tools, 3D printing for prosthetics, and eco-friendly sterilization solutions. Digital X-rays with enhanced imaging software are also gaining traction.
Calibration ensures accuracy, safety, and compliance with regulations. Most equipment, such as X-rays and sterilizers, should be calibrated annually or whenever performance issues arise.